Fall Protection
from OSHA's Construction Safety and Health Outreach Program
INTRODUCTION
In the construction industry in the U.S., falls are the leading cause of
worker fatalities. Each year, on average, between 150 and 200 workers are killed and more
than 100,000 are injured as a result of falls at construction sites. OSHA recognizes that
accidents involving falls are generally complex events frequently involving a variety of
factors. Consequently the standard for fall protection deals with both the human and
equipment-related issues in protecting workers from fall hazards. For example, employers
and employees need to do the following:
- Where protection is required, select fall protection systems appropriate
for given situations.
- Use proper construction and installation of safety systems.
- Supervise employees properly.
- Use safe work procedures.
- Train workers in the proper selection, use, and maintenance of all
protection systems.
SCOPE AND APPLICATION
OSHA has revised its construction industry safety standards (29 Code
of Federal Regulations, Subpart M, Fall Protection, 1926.500, 1926.501, 1926.502, and
1926.503) and developed systems and procedures designed to prevent employees from falling
off, onto, or through working levels and to protect employees from being struck by falling
objects (Federal Register, August 9, 1994, pp. 40672-40753). The
performance-oriented requirements make it easier for employers to provide the necessary
protection.
The rule covers most construction workers except those inspecting,
investigating, or assessing workplace conditions prior to the actual start of work or
after all work has been completed.
The rule identifies areas or activities where fall protection is needed.
These include, but are not limited to, ramps, runways, and other walkways; excavations;
hoist areas; holes; formwork and reinforcing steel; leading edge work; unprotected sides
and edges; overhand bricklaying and related work; roofing work; precast concrete erection;
wall openings; residential construction; and other walking/working surfaces. The rule sets
a uniform threshold height of 6 feet (1.8 meters), thereby providing consistent
protection. This means that construction employers must protect their employees from fall
hazards and falling objects whenever an affected employee is 6 feet (1.8 meters) or more
above a lower level. Protection must also be provided for construction workers who are
exposed to the hazard of falling into dangerous equipment.
Under the new standard, employers will be able to select fall protection
measures compatible with the type of work being performed. Fall protection generally can
be provided through the use of guardrail systems, safety net systems, personal fall arrest
systems, positioning device systems, and warning line systems, among others.
The OSHA rule clarifies what an employer must do to provide fall
protection for employees, such as identifying and evaluating fall hazards and providing
specific training. Requirements to provide fall protection for workers on scaffolds and
ladders and for workers engaged in steel erection of buildings arc covered in other
subparts of OSHA regulations.
PROVISIONS OF THE STANDARD
The new standard prescribes the duty to provide fall protection, sets
the criteria and practices for fall protection systems, and requires training. It covers
hazard assessment and fall protection and safety monitoring systems. Also addressed are
controlled access zones, safety nets, and guardrail, personal fall arrest, warning line,
and positioning device systems.
DUTY TO HAVE FALL PROTECTION
Employers are required to assess the workplace to determine if the
walking/working surfaces on which employees are to work have the strength and structural
integrity to safely support workers. Employees are not permitted to work on those surfaces
until it has been determined that the surfaces have the requisite strength and structural
integrity to support the workers. Once employers have determined that the surface is safe
for employees to work on, the employer must select one of the options listed for the work
operation if a fall hazard is present.
For example, if an employee is exposed to falling 6 feet (l .8 meters)
or more from an unprotected side or edge, the employer must select either a guardrail
system, safety net system, or personal fall arrest system to protect the worker. Similar
requirements are prescribed for other fall hazards as follows.
Controlled Access Zones
A Controlled access zone is a work area designated and clearly marked in
which certain types of work (such as overhand bricklaying) may take place without the use
of conventional fall protection systems - guardrail, personal arrest or safety
net - to protect the employees working in the zone.
Controlled access zones are used to keep out workers other than those
authorized to enter work areas from which guardrails have been removed. Where there are no
guardrails, masons are the only workers allowed in controlled access zones.
Controlled access zones, when created to limit entrance to areas where
leading edge work and other operations are taking place, must be defined by a control line
or by any other means that restrict access. Control lines shall consist of ropes, wires,
tapes or equivalent materials, and supporting stanchions, and each must be:
- Flagged or otherwise clearly marked at not more than 6-foot (1.8 meters)
intervals with high-visibility material;
- Rigged and supported in such a way that the lowest point (including sag)
is not less than 39 inches (1 meter) from the walking/working surface and the highest
point is not more than 45 inches (1.3 meters) - nor more than 50 inches (1.3 meters)
when overhand bricklaying operations are being performed - from the walking/working
surface;
- Strong enough to sustain stress of not less than 200 pounds (0.88
kilonewtons). Control lines shall extend along the entire length of the unprotected or
leading edge and shall be approximately parallel to the unprotected or leading edge.
- Control lines also must be connected on each side to a guardrail system
or wall.
When control lines are used, they shall be erected not less than 6 feet
(1.8 meters) nor more than 25 feet (7.6 meters) from the unprotected or leading edge,
except when precast concrete members are being erected. In the latter case, the control
line is to be erected not less than 6 feet (1.8 meters) nor more than 60 feet (18 meters)
or half the length of the member being erected, whichever is less, from the leading edge.
Controlled access zones when used to determine access to areas where overhand
bricklaying and related work are taking place are to be defined
by a control line erected not less than 10 feet (3 meters) nor more than 15 feet (4.6
meters) from the working edge. Additional control lines must be erected at each end to
enclose the controlled access zone. Only employees engaged in overhand bricklaying or
related work are permitted in the controlled access zones.
On floors and roofs where guardrail systems are not in place prior to
the beginning of overhand bricklaying operations, controlled access zones will be enlarged
as necessary to enclose all points of access, material handling areas, and storage areas.
On floors and roofs where guardrail systems are in place, but need to be removed to allow
overhand bricklaying work or leading edge work to take place, only that portion of the
guardrail necessary to accomplish that day's work shall be removed.
Excavations
Each employee at the edge of an excavation 6 feet (1.8 meters) or more
deep shall be protected from falling by guardrail systems, fences, barricades, or covers.
Where walkways are provided to permit employees to cross over excavations, guardrails are
required on the walkway if it is 6 feet (1.8 meters) or more above the excavation.
Formwork and Reinforcing Steel
For employees, while moving vertically and/or horizontally on the
vertical face of rebar assemblies built in place, fall protection is not required when
employees are moving. OSHA considers the multiple hand holds and foot holds on rebar
assemblies as providing similar protection as that provided by a fixed ladder;
consequently, no fall protection is necessary while moving point to point for heights
below 24 feet (7.3 meters). An employee must be provided with fall protection when
climbing or otherwise moving at a height more than 24 feet (7.3 meters), the same as for
fixed ladders.
Hoist Areas
Each employee in a hoist area shall be protected from falling 6 feet
(1.8 meters) or more by guardrail systems or personal fall arrest systems. If guardrail
systems (or chain gate or guardrail) or portions thereof must be removed to facilitate
hoisting operations, as during the landing of materials, and a worker must lean through
the access opening or out over the edge of the access opening to receive or guide
equipment and materials, that employee must be protected by a personal fall arrest system.
Holes
Personal fall arrest systems, covers, or guardrail systems shall be
erected around holes (including skylights) that are more than 6 feet (1.8 meters) above
lower levels.
Leading Edges
Each employee who is constructing a leading edge 6 feet (1.8 meters) or
more above lower levels shall be protected by guardrail systems, safety net systems, or
personal fall arrest systems. If the employer can demonstrate that it is infeasible or
creates a greater hazard to implement these systems, he or she must develop and implement
a fall protection plan that meets the requirements of 29 CFR 1926.502(k).
Overhand Bricklaying and Related Work
Each employee performing overhand bricklaying and related work 6 feet
(1.8 meters) or more above lower levels shall be protected by guardrail systems, safety
net systems, or personal fall arrest systems, or shall work in a controlled access zone.
All employees reaching more than 10 inches (25 cm) below the level of a walking/working
surface on which they are working shall be protected by a guardrail system, safety net
system, or personal fall arrest system.
Precast Concrete Erection and Residential Construction
Each employee who is 6 feet (1.8 meters) or more above lower levels
while erecting precast concrete members and related operations such as grouting of precast
concrete members and each employee engaged in residential construction, shall be protected
by guardrail systems, safety net systems, or personal fall arrest systems. Where the
employer can demonstrate, however, that it is infeasible or creates a greater hazard to
use those systems, the employer must develop and implement a fall protection plan that
meets the requirements of 29 CFR 1926.502(k).
Ramps, Runways, and Other Walkways
Each employee using ramps, runways, and other walkways shall be
protected from falling 6 feet (1.8 meters) or more by guardrail systems.
Roofing
Low-slope Roofs
Each employee engaged in roofing activities on low-slope roofs with
unprotected sides and edges 6 feet (1.8 meters) or more above lower levels shall be
protected from falling by guardrail systems, safety net systems, personal fall arrest
systems or a combination of a warning line system and guardrail system, warning line
system and safety net system, warning line system and personal fall arrest system, or
warning line system and safety monitoring system. On roofs 50 feet (15.24 meters) or less
in width, the use of a safety monitoring system without a warning line system is
permitted.
Steep Roofs
Each employee on a steep roof with unprotected sides and edges 6 feet
(1.8 meters) or more above lower levels shall be protected by guardrail systems with
toeboards, safety net systems, or personal fall arrest systems.
Wall Openings
Each employee working on, at, above, or near wall openings (including
those with chutes attached) where the outside bottom edge of the wall opening is 6 feet
(1.8 meters) or more above lower levels and the inside bottom edge of the wall opening is
less than 39 inches (1.0 meter) above the walking/working surface must be protected from
falling by the use of a guardrail system, a safety net system, or a personal fall arrest
system.
FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES
Guardrail Systems
If the employer chooses to use guardrail systems to protect workers from
falls, the systems must meet the following criteria. Toprails and midrails of guardrail
systems must be at least one-quarter inch (0.6 centimeters) nominal diameter or thickness
to prevent cuts and lacerations. If wire rope is used for toprails, it must be flagged at
not more 6 feet intervals (1.8 meters) with high-visibility material. Steel and plastic
banding cannot be used as toprails or midrails. Manila, plastic, or synthetic rope used
for toprails or midrails must be inspected as frequently as necessary to ensure strength
and stability.
The top edge height of toprails, or (equivalent) guardrails must be 42
inches (1.1 meters) plus or minus 3 inches (8 centimeters), above the walking/working
level. When workers are using stilts, the top edge height of the top rail, or equivalent
member, must be increased an amount equal to the height of the stilts.
Screens, midrails, mesh, intermediate vertical members, or equivalent
intermediate structural members must be installed between the top edge of the guardrail
system and the walking/working surface when there are no walls or parapet walls at least
21 inches (53 centimeters) high. When midrails are used, they must be installed at a
height midway between the top edge of the guardrail system and the walking/working level.
When screens and mesh are used, they must extend from the top rail to the walking/working
level and along the entire opening between top rail supports. Intermediate members, such
as balusters, when used between posts, shall not be more than 19 inches (48 centimeters)
apart.
Other structural members, such as additional midrails and architectural
panels, shall be installed so that there are no openings in the guardrail system more than
19 inches (48 centimeters).
The guardrail system must be capable of withstanding a force of at least
200 pounds (890 newtons) applied within 2 inches of the top edge in any outward or
downward direction. When the 200 pound (890 newtons) test is applied in a downward
direction, the top edge of the guardrail must not deflect to a height less than 39 inches
(1 meter) above the walking/working level.
Midrails, screens, mesh, intermediate vertical members, solid panels,
and equivalent structural members shall be capable of withstanding a force of at least 150
pounds (667 newtons) applied in any downward or outward direction at any point along the
midrail or other member.
Guardrail systems shall be surfaced to protect workers from punctures or
lacerations and to prevent clothing from snagging.
The ends of top rails and midrails must not overhang terminal posts,
except where such overhang does not constitute a projection hazard.
When guardrail systems are used at hoisting areas, a chain, gate, or
removable guardrail section must be placed across the access opening between guardrail
sections when hoisting operations are not taking place.
At holes, guardrail systems must be set up on all unprotected sides or
edges. When holes are used for the passage of materials, the hole shall have not more than
two sides with removable guardrail sections. When the hole is not in use, it must be
covered or provided with guardrails along all unprotected sides or edges.
If guardrail systems are used around holes that are used as access
points (such as ladderways), gates must be used or the point of access must be offset to
prevent accidental walking into the hole.
If guardrails are used at unprotected sides or edges of ramps and
runways, they must be erected on each unprotected side or edge.
Personal Fall Arrest Systems
These consist of an anchorage, connectors, and a body belt or body
harness and may include a deceleration device, lifeline, or suitable combinations. If a
personal fall arrest system is used for fall protection, it must do the following:
- Limit maximum arresting force on an employee to 900 pounds (4
kilonewtons) when used with a body belt;
- Limit maximum arresting force on an employee to 1,800 pounds (8
kilonewtons) when used with a body harness;
- Be rigged so that an employee can neither free fall more than 6 feet (1.8
meters) nor contact any lower level;
- Bring an employee to a complete stop and limit maximum deceleration
distance an employee travels to 3.5 feet (1.07 meters); and
- Have sufficient strength to withstand twice the potential impact energy
of an employee free falling a distance of 6 feet (1.8 meters) or the free fall distance
permitted by the system, whichever is less.
As of January 1, 1998, the use of a body belt for fall arrest is
prohibited.
Personal fall arrest systems must be inspected prior to each use for
wear damage, and other deterioration. Defective components must be removed from service.
Dee-rings and snaphooks must have a minimum tensile strength of 5,000 pounds (22.2
kilonewtons). Dee-rings and snaphooks shall be proof-tested to a minimum tensile load of
3,600 pounds (16 kilonewtons) without cracking, breaking, or suffering permanent
deformation.
Snaphooks shall be sized to be compatible with the member to which they
will be connected, or shall be of a locking configuration.
Unless the snaphook is a locking type and designed for the following
connections, they shall not be engaged (a) directly to webbing, rope or wire rope; (b) to
each other; (c) to a dee-ring to which another snaphook or other connecter is attached;
(d) to a horizontal lifeline; or (e) to any object incompatible in shape or dimension
relative to the snaphook, thereby causing the connected object to depress the snaphook
keeper and release unintentionally.
OSHA considers a hook to be compatible when the diameter of the dee-ring
to which the snaphook is attached is greater than the inside length of the snaphook when
measured from the bottom (hinged end) of the snaphook keeper to the inside curve of the
top of the snaphook. Thus, no matter how the dee-ring is positioned or moved (rolls) with
the snaphook attached, the dee-ring cannot touch the outside of the keeper, thus
depressing it open. As of January 1, 1998, the use of nonlocking snaphooks is prohibited.
On suspended scaffolds or similar work platforms with horizontal
lifelines that may become vertical lifelines, the devices used to connect to a horizontal
lifeline shall be capable of locking in both directions on the lifeline.
Horizontal lifelines shall be designed, installed, and used under the
supervision of a qualified person, as part of a complete personal fall arrest system that
maintains a safety factor of at least two. Lifelines shall be protected against being cut
or abraded.
Self-retracting lifelines and lanyards that automatically limit free
fall distance to 2 feet (0.6 l meters) or less shall be capable of sustaining a minimum
tensile load of 3,000 pounds (13.3 kilonewtons) applied to the device with the lifeline or
lanyard in the fully extended position.
Self-retracting lifelines and lanyards that do not limit free fall
distance to 2 feet (0.61 meters) or less, ripstitch lanyards, and tearing and deforming
lanyards shall be capable of sustaining a minimum tensile load of 5,000 pounds (22.2
kilonewtons) applied to the device with the lifeline or lanyard in the fully extended
position.
Ropes and straps (webbing) used in lanyards, lifelines, and strength
components of body belts and body harnesses shall be made of synthetic fibers.
Anchorages shall be designed, installed, and used under the supervision
of a qualified person, as part of a complete personal fall arrest system that maintains a
safety factor of at least two, i.e., capable of supporting at least twice the weight
expected to be imposed upon it. Anchorages used to attach personal fall arrest systems
shall be independent of any anchorage being used to support or suspend platforms and must
be capable of supporting at least 5,000 pounds (22.2 kilonewtons) per person attached.
Lanyards and vertical lifelines must have a minimum breaking strength of
5,000 pounds (22.2 kilonewtons).
Positioning Device Systems
These body belt or body harness systems are to be set up so that a
worker can free fall no farther than 2 feet (0.6 meters). They shall be secured to an
anchorage capable of supporting at least twice the potential impact load of an employee's
fall or 3,000 pounds (13.3 kilonewtons), whichever is greater. Requirements for snaphooks,
dee-rings, and other connectors used with positioning device systems must meet the same
criteria as those for personal fall arrest systems.
Safety Monitoring Systems
When no other alternative fall protection has been implemented, the
employer shall implement a safety monitoring system. Employers must appoint a competent
person to monitor the safety of workers and the employer shall ensure that the safety
monitor:
- Is competent in the recognition of fall hazards;
- Is capable of warning workers of fall hazard dangers and in detecting
unsafe work practices;
- Is operating on the same walking/working surfaces of the workers and can
see them;
- Is close enough to work operations to communicate orally with workers and
has no other duties to distract from the monitoring function.
Mechanical equipment shall not be used or stored in areas where safety
monitoring systems are being used to monitor employees engaged in roofing operations on
low-sloped roofs.
No worker, other than one engaged in roofing work (on low-sloped roofs)
or one covered by a fall protection plan, shall be allowed in an area where an employee is
being protected by a safety monitoring system.
All workers in a controlled access zone shall be instructed to promptly
comply with fall hazard warnings issued by safety monitors.
Safety Net Systems
Safety nets must be installed as close as practicable under the
walking/working surface on which employees are working and never more than 30 feet (9.1
meters) below such levels. Defective nets shall not be used. Safety nets shall be
inspected at least once a week for wear, damage, and other deterioration. The maximum size
of each safety net mesh opening shall not exceed 36 square inches (230 square centimeters)
nor be longer than 6 inches (15 centimeters) on any side, and the openings, measured
center-to-center, of mesh ropes or webbing, shall not exceed 6 inches (15 centimeters).
All mesh crossings shall be secured to prevent enlargement of the mesh opening. Each
safety net or section shall have a border rope for webbing with a minimum breaking
strength of 5,000 pounds (22.2 kilonewtons). Connections between safety net panels shall
be as strong as integral net components and be spaced no more than 6 inches (15
centimeters) apart.
Safety nets shall be installed with sufficient clearance underneath to
prevent contact with the surface or structure below.
When nets are used on bridges, the potential fall area from the
walking/working surface to the net shall be unobstructed.
Safety nets must extend outward from the outermost projection of the
work surface as follows:
| Vertical distance from working level
to horizontal plane of net. |
Minimum required horizontal distance
of outer edge of net from the edge of the working surface. |
| Up to 5 feet (1.5 meters) |
8 feet (2.4 meters) |
| More than 5 feet (1.5 meters) up to 10 feet (3 meters) |
10 feet (3 meters) |
| More than 10 feet (3 meters) |
13 feet (3.9 meters) |
Safety nets shall be capable of absorbing an impact force of a drop test
consisting of a 400-pound (180 kilogram) bag of sand 30 inches (76 centimeters) in
diameter dropped from the highest walking/working surface at which workers are exposed,
but not from less than 42 inches (1.1 meters) above that level.
Items that have fallen into safety nets including - but not
restricted to, materials, scrap, equipment, and tools - must be removed as soon as
possible and at least before the next work shift.
Warning Line Systems
Warning line systems consist of ropes, wires, or chains, and supporting
stanchions and are set up as follows:
- Flagged at not more than 6-foot (1.8 meters) intervals with
high-visibility material;
- Rigged and supported so that the lowest point (including sag) is no less
than 34 inches (0.9 meters) from the walking/working surface and its highest point is no
more than 39 inches (1 meter) from the walking/working surface.
- Stanchions, after being rigged with warning lines, shall be capable of
resisting, without tipping over, a force of at least 16 pounds (71 newtons) applied
horizontally against the stanchion, 30 inches (0.8 meters) above the walking/working
surface, perpendicular to the warning line and in the direction of the floor, roof, or
platform edge;
- The rope, wire, or chain shall have a minimum tensile strength of 500
pounds (2.22 kilonewtons) and after being attached to the stanchions, must support without
breaking, the load applied to the stanchions as prescribed above.
- Shall be attached to each stanchion in such a way that pulling on one
section of the line between stanchions will not result in slack being taken up in the
adjacent section before the stanchion tips over.
Warning lines shall be erected around all sides of roof work areas. When
mechanical equipment is being used, the warning line shall be erected not less than 6 feet
(1.8 meters) from the roof edge parallel to the direction of mechanical equipment
operation, and not less than 10 feet (3 meters) from the roof edge perpendicular to the
direction of mechanical equipment operation.
When mechanical equipment is not being used, the warning line must be
erected not less than 6 feet (1.8 meters) from the roof edge.
Covers
Covers located in roadways and vehicular aisles must be able to support
at least twice the maximum axle load of the largest vehicle to which the cover might be
subjected. All other covers must be able to support at least twice the weight of
employees, equipment, and materials that may be imposed on the cover at any one time. To
prevent accidental displacement resulting from wind, equipment, or workers' activities,
all covers must be secured. All covers shall be color coded or bear the markings
"HOLE" or "COVER."
PROTECTION FROM FALLING OBJECTS
When guardrail systems are used to prevent materials from falling from
one level to another, any openings must be small enough to prevent passage of potential
falling objects. No materials or equipment except masonry and mortar shall be stored
within 4 feet (1.2 meters) of working edges. Excess mortar, broken or scattered masonry
units, and all other materials and debris shall be kept clear of the working area by
removal at regular intervals.
During roofing work, materials and equipment shall not be stored within
6 feet (1.8 meters) of a roof edge unless guardrails are erected at the edge, and
materials piled, grouped, or stacked near a roof edge must be stable and self-supporting.
Canopies
When used as protection from falling objects canopies must be strong
enough to prevent collapse and to prevent penetration by any objects that may fall onto
them.
Toeboards
When toeboards are used as protection from falling objects, they must be
erected along the edges of the overhead walking/working surface for a distance sufficient
to protect persons working below. Toeboards shall be capable of withstanding a force of at
least 50 pounds (222 newtons) applied in any downward or outward direction at any point
along the toeboard. Toeboards shall be a minimum of 3.5 inches (9 centimeters) tall from
their top edge to the level of the walking/working surface, have no more than 0.25 inches
(0.6 centimeters) clearance above the walking/working surface, and be solid or have
openings no larger than l inch (2.5 centimeters) in size.
Where tools, equipment, or materials are piled higher than the top edge
of a toeboard, panelling or screening must be erected from the walking/working surface or
toeboard to the top of a guardrail system's top rail or midrail, for a distance sufficient
to protect employees below.
TRAINING
Employers must provide a training program that teaches employees who
might be exposed to fall hazards how to recognize such hazards and how to minimize them.
Employees must be trained in the following areas: (a) the nature of fall hazards in the
work area; (b) the correct procedures for erecting, maintaining, disassembling,
and inspecting fall protection systems; (c) the use and operation of
controlled access zones and guardrail, personal fall arrest, safety net, warning line, and
safety monitoring systems; (d) the role of each employee in the safety monitoring system
when the system is in use; (e) the limitations on the use of mechanical equipment during
the performance of roofing work on low-sloped roofs; (f) the correct procedures for
equipment and materials handling and storage and the erection of overhead protection; and,
(g) employees' role in fall protection plans.
Employers must prepare a written certification that identifies the
employee trained and the date of the training. The employer or trainer must sign the
certification record. Retraining also must be provided when necessary.
Glossary
Anchorage - A secure point of attachment for
lifelines, lanyards or deceleration devices.
Body belt - A strap with means both for securing it
about the waist and for attaching it to a lanyard, lifeline, or deceleration device.
Body harness - -Straps that may be secured about
the person in a manner that distributes the fall-arrest forces over at least the thighs,
pelvis, waist, chest, and shoulders with a means for attaching the harness to other
components of a personal fall arrest system.
Connector - A device that is used to couple
(connect) parts of a personal fall arrest system or positioning device system together.
Controlled access zone - A work area designated and
clearly marked in which certain types of work (such as overhand bricklaying) may take
place without the use of conventional fall protection systems - guardrail, personal
arrest or safety net - to protect the employees working in the zone.
Deceleration device - Any mechanism - such as
rope, grab, ripstitch lanyard, specially-woven lanyard, tearing or deforming lanyards,
automatic self-retracting lifelines/lanyards - which serves to dissipate a substantial
amount of energy during a fall arrest, or otherwise limits the energy imposed on an
employee during fall arrest.
Deceleration distance - The additional vertical
distance a falling person travels, excluding lifeline elongation and free fall distance,
before stopping, from the point at which a deceleration device begins to operate.
Guardrail system - A barrier erected to prevent
employees from falling to lower levels.
Hole - A void or gap 2 inches (5.1 centimeters) or
more in the least dimension in a floor, roof, or other walking/working surface.
Lanyard - A flexible line of rope, wire rope, or
strap that generally has a connector at each end for connecting the body belt or body
harness to a deceleration device, lifeline, or anchorage.
Leading edge - The edge of a floor, roof, or
formwork for a floor or other walking/working surface (such as the deck) which changes
location as additional floor, roof, decking, or formwork sections are placed, formed or
constructed.
Lifeline - A component consisting of a flexible line
for connection to an anchorage at one end to hang vertically (vertical lifeline), or for
connection to anchorages at both ends to stretch horizontally (horizontal lifeline) and
that serves as a means for connecting other components of a personal fall arrest system to
the anchorage.
Low-slope roof - A roof having a slope less than or
equal to 4 in 12 (vertical to horizontal).
Opening - A gap or void 30 inches (76 centimeters)
or more high and 18 inches (46 centimeters) or more wide, in a wall or partition, through
which employees can fall to a lower level.
Personal fall arrest system - A system including but
not limited to an anchorage, connectors, and a body belt or body harness used to arrest an
employee in a fall from a working level. As of January 1, 1998, the use of a body belt for
fall arrest is prohibited.
Positioning device system - A body belt or body
harness system rigged to allow an employee to be supported on an elevated vertical
surface, such as a wall, and work with both hands free while leaning backwards.
Rope grab - A deceleration device that travels on a
lifeline and automatically, by friction, engages the lifeline and locks to arrest a fall.
Safety-monitoring system - A safety system in which
a competent person is responsible for recognizing and warning employees of fall hazards.
Self-retracting lifeline/lanyard - A deceleration
device containing a drum-wound line which can be slowly extracted from, or retracted onto,
the drum under minimal tension during normal employee movement and which, after onset of a
fall, automatically locks the drum and arrests the fall.
Snaphook - A connector consisting of a hook-shaped
member with a normally closed keeper, or similar arrangement, which may be opened to
permit the hook to receive an object and, when released automatically closes to retain the
object.
Steep roof - A roof having a slope greater than 4 in
12 (vertical to horizontal).
Toeboard - A low protective barrier that prevents
material and equipment from falling to lower levels and which protects personnel from
falling.
Unprotected sides and edges - Any side or edge
(except at entrances to points of access) of a walking/working surface (e.g. floor, roof,
ramp, or runway) where there is no wall or guardrail system at least 39 inches (1 meter)
high.
Walking/working surface - Any surface, whether
horizontal or vertical, on which an employee walks or works, including but not limited to
floors, roofs, ramps, bridges, runways, formwork, and concrete reinforcing steel. Does not
include ladders, vehicles, or trailers on which employees must be located to perform their
work duties.
Warning line system - A barrier erected on a roof to
warn employees that they are approaching an unprotected roof side or edge and which
designates an area in which roofing work may take place without the use of guardrail, body
belt, or safety net systems to protect employees in the area.
|